| Size |
20A,25A,40A |
| Flow range |
15-6,500L/h |
| Viscosity |
0.5-10,000mPas |
| Temperature |
-10 to
80 deg C |
| Pressure |
Working pressure-Less than 1.0MPa |
| Accuracy |
Within +-0.5% |
| Indication |
*Total integrated flow rate |
| *Momentary flow rate ( /h) or ( /min) |
| *Integrated flow rate (resettable) |
| *Momentary flow rate (%) |
| *Alarm for excessive flow |
| *Alarm for high flow |
| *Alarm for low flow |
| *Alarm for battery |
| Output signal |
*Analog type: 4-20mADC |
| *Pulse, alarm type: pulse signal or alarm signal |
| Material |
Body: SCS14 |
| Rotor: PPS resin |
| Eccentric bearing: Carbon |
| Construction |
Explosion-proof and frame-proof type
ExdIIBT4 |
|
|
|