Size |
25A,40A,50A,80A,100A |
Flow range |
200(special spec.: 40) - 50,000L/h |
Viscosity |
0.5-500mPas |
Special spec. (0.3-30,000mPas) |
Temperature |
-10 to 80 deg C |
Special spec. (-10 to 150 deg C) |
Pressure |
Working pressure-less than 1.0MPa |
Special spec. (Less than 2.0MPa) |
Accuracy |
Within +-0.2% |
Special spec. (within +-0.5%) |
Indication |
*Total integrated flow rate |
*Instantaneous flow rate ( /h) or ( /min) |
*Integrated flow rate (Resettable) |
*Instantaneous flow rate (%) |
*Alarm for excessive flow |
*Alarm for high flow |
*Alarm for low flow |
*Alarm for battery |
Output signal |
*Analog: 4-20mADC |
*Pulse, alarm: voltage contactless or open collector |
Material |
FC200/CAC406 |
FC200/FC200 |
FC200/SCS14 |
SCS14/SCS14 |
Construction |
Field totalizing type: Instinct-safe type Exia IIBT4 |
Signal output type: Explosion-proof and frame-proof type Exd IIBT4X |